Patient Vitals Monitor

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Hebei
Validity to: Long-term effective
Last update: 2021-05-31 16:30
Browse the number: 158
inquiry
Company Profile
 
 
Product details

CONTEC CMS5100 2.8"TFT Patient Vitals Monitor


Introduction


CMS5100 Patient Vitals Monitor is a feature-rich monitoring device that can be applied to adults, pediatric and neonate. User can choose different measurement parameters according to different needs. The patient monitor can monitor NIBP, SpO2 and PR. It integrates the function of parameter measuring and displaying into a compact, lightweight patient monitor, which is suitable for all levels of hospitals, community medical and home use.


Features


1) Be applicable for NIBP and SpO2 monitoring of adult, pediatric and neonate of all ages, easy to operate, high cost-effective;

2) Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics;

3) Compact and flexible appearance, easy for carrying and suitable for indoor and outdoor (in ambulance) monitoring;

4) Built-in rechargeable lithium polymer battery, ensuring uninterrupted monitoring;

5) Perfect menu design, user-friendly interface;

6) Display the measurement result of SYS, DIA, MAP, SpO2, PR and bar graph by the display screen of high-brightness digital tube;

7) 2.8'' (320×240) true color TFT LCD screen, displays the information of time, SpO2 Plethysmogram, alarm condition, trend graph, list and system settings, etc.;

8) Visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, and upper and lower limit of alarm can be set as necessary;

9) Independent nonvolatile memory, storage for up to 2,000 groups of NIBP data and 78,000 groups of SpO2 data;

10) Patient Vitals Monitor is convenient and quick in reviewing measurement data, available for reviewing the NIBP trend graph of 24 hours and SpO2 trend graph of 22 hours.


Performance


1 NIBP

Using Oscillometry technology, also called Oscillography technology to measure the blood pressure.


Measurement mode

Manual/auto/continuous

Measurement interval in auto mode

1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min.

Resolution

1 mmHg

Accuracy

max mean error: ±5 mmHg

max standard deviation: 8 mmHg

Overpressure protection

dual protection for both software and hardware

Others

reset, self-testing and accuracy testing of static pressure

Measurement range


Adult

SYS 40 mmHg~270 mmHg

MAP 20 mmHg~235 mmHg

DIA 10 mmHg~215 mmHg

Pediatric

SYS 40 mmHg~200 mmHg

MAP 20 mmHg~165 mmHg

DIA 10 mmHg~150 mmHg

Neonate

SYS 40 mmHg~135 mmHg

MAP 20 mmHg~110 mmHg

DIA 10 mmHg~100 mmHg


2 SpO2

Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the saturation of blood oxygen.


Measurement range

0 %~100 %

Alarm range

0 %~100 %

Resolution

1 %

Accuracy

70 %~100 %, ±2 %

below 70 % unspecified


3 PR

Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the pulse rate.


Measurement range

25 bpm~250 bpm

Alarm range

25 bpm~250 bpm

Resolution

1 bpm

Accuracy

±2 bpm or ±2 %, whichever is greater


4 Safety and Power supply

1)Power supply: rated voltage: ~220 V, rated power: 50 Hz

2)Safety classification: Class I equipment, type BF defibrillation-proof applied part


Accessories


1)User Manual-1piece

2)Power cord-1piece

3)Power adapter-1piece

4)SpO2 sensor-1piece

5)Adult NIBP cuff-1piece

6)NIBP extension tube-1piece


Physical characteristic


Dimension: 190 mm(L)×162 mm(W)×240 mm(H)

Weight: about 1.6 kg



More info you need about our patient vitals monitors, please feel free to contact us!


http://www.contecmedsystems.com/

Total0bar [View All]  Related Comments
 
more»Other products